CLAMP EARTH GROUND TESTER

UNI-T CLAMP EARTH GROUND TESTER UT276A+ | DATA HOLD AND RECALL | AUTO CALIBRATION AND RANGE | LCD BACKLIGHT | RESISTANCE LIMIT ALARM

SKU: UNITUT276+ Barcode: 6935750527627 Category: ELECTRICAL TESTING TOOLS
AED 1,120.00
In Stock
6 MONTHS
Free Delivery
MADE IN CHINA
15 Days Return
Cash on Delivery
Expected Delivery: 22-09-2026
Max: 36

Description

BRAND : UNI-T

ITEM NO.: UT276A+

ORIGIN : CHINA

DISPLAY COUNT : 4 DIGITS LCD DISPLAY

JAW OPENING : 32MM

VISUAL AND AUDIBLE ALARM : βœ”

AUTO POWER OFF : βœ”

JAMMING SIGNAL RECOGNITION : βœ”

OVER-RANGE DISPLAY : βœ”

DATA STORAGE : 300

DISPLAY TYPE : EBTN

POWER : 1.5V BATTERY (LR6) X 4

DISPLAY : 47MM X 28.5MM

PRODUCT NET WEIGHT : 1.18KG

PRODUCT SIZE 278A+ : 285MM X 85MM X 56MM

STANDARD ACCESSORIES : BATTERIES, TEST RING, ENGLISH MANUAL

STANDARD INDIVIDUAL PACKING : GIFT BOX, TOOL BOX

STANDARD CARTON MEASUREMENT : 370MM X 110MM X 300MM

STANDARD CARTON GROSS WEIGHT UT276A : 2.6KG


EARTH GROUND RESISTANCE (Ξ©) : 

RANGE :

0.01~0.099Ξ©, Β±(1%+0.01)

0.1~0.99Ξ©, Β±(1%+0.01)

1~49.9Ξ©, Β±(1%+0.1)

50~99.5Ξ©, Β±(1.5%+0.5)

100~199Ξ©, Β±(2%+1)

200~395Ξ©, Β±(5%+5)

400~590Ξ©, Β±(10%+10)

600~800Ξ©

600~1000Ξ©

800~1200Ξ©


LEAKAGE CURRENT (A) :

0MA~9MA

10MA~99MA

100MA~299MA

0MA~299MA

0.3A~2.99A

3A~9.9A

10A~20A

3A~30A


. CERTIFICATES: CE, UKCA

. AUTO RANGE

. DATA HOLD

. DATA RECALL

. LCD BACKLIGHT

. RESISTANCE LIMIT ALARM

. LOW BATTERY INDICATION

. AUTO CALIBRATION

Specifications

Item Code UNITUT276+
Barcode 6935750527627
Brand UNI-T

About Product

UNI-T UT276A+ Clamp Earth Ground Tester

The UNI-T UT276A+ Clamp Earth Ground Tester is a professional electrical testing instrument designed for measuring earth ground resistance and leakage current without requiring traditional disconnection-based testing methods. Its clamp-style design provides a convenient way for qualified technicians to inspect grounding systems, electrical installations, equipment, and leakage conditions.

Featuring auto ranging, auto calibration, data hold, data recall, LCD backlight, resistance limit alarm, visual and audible alarms, and data storage, the UT276A+ is designed to make routine grounding and electrical safety inspections more efficient and convenient.

What Is the UNI-T UT276A+ Used For?

The UNI-T UT276A+ is used to check earth ground resistance and leakage current in electrical grounding systems. It helps technicians evaluate whether grounding paths are performing within an acceptable range and identify abnormal leakage current conditions.

Because the instrument uses a clamp-style measurement method, it can be particularly useful for inspecting grounding conductors and electrical systems where disconnecting the grounding connection would be inconvenient or undesirable.

The UT276A+ is therefore a useful tool for electrical maintenance, grounding system inspection, facility maintenance, industrial troubleshooting, and electrical safety checks.

How to Use the UNI-T UT276A+ Clamp Earth Ground Tester?

  1. Inspect the tester: Check the instrument, clamp jaws, battery condition, and accessories before starting the measurement.
  2. Switch on the tester: Power on the UT276A+ and allow the instrument to initialize.
  3. Select the appropriate measurement: Choose the required earth ground resistance or leakage current measurement function.
  4. Open the clamp jaw: Place the clamp around the appropriate grounding conductor or conductor under test according to the measurement procedure.
  5. Close the clamp securely: Ensure the clamp is properly closed and positioned around the conductor before taking the reading.
  6. Read the measurement: Observe the resistance or current value on the LCD display.
  7. Use auto range when required: Allow the instrument to automatically select an appropriate measurement range.
  8. Use the alarm function: Set the resistance limit when required so the tester can provide visual or audible indication when the configured limit is exceeded.
  9. Hold or recall data: Use the data hold and recall functions when measurements need to be reviewed or recorded.
  10. Complete the inspection: Remove the clamp carefully after the measurement and switch off the instrument when finished.

Important: Electrical grounding and leakage measurements can involve hazardous electrical systems. The UT276A+ should be operated only by appropriately trained personnel following the instrument manual, local electrical regulations, and required safety procedures.

What Are the Key Features of the UNI-T UT276A+?

  • Clamp earth ground testing for convenient grounding system inspection.
  • Earth ground resistance measurement for evaluating grounding conditions.
  • Leakage current measurement for identifying abnormal current conditions.
  • Auto ranging automatically selects a suitable measurement range.
  • Auto calibration helps simplify instrument preparation before measurement.
  • Data hold function allows users to freeze a displayed measurement for easier viewing.
  • Data recall function allows stored measurement results to be reviewed.
  • Up to 300 measurement records can be stored for later reference.
  • Resistance limit alarm helps alert users when the configured resistance condition is exceeded.
  • Visual and audible alarms provide additional measurement alerts.
  • LCD backlight improves display visibility in darker working areas.
  • Jamming signal recognition helps identify interfering signals during measurement.
  • Low battery indication alerts the user when battery power is low.
  • Over-range indication helps identify measurements outside the available range.
  • Compact clamp design makes the instrument practical for field and maintenance work.

Why Choose the UNI-T UT276A+?

The UNI-T UT276A+ is a practical choice for professionals who regularly inspect grounding systems and need a portable instrument for resistance and leakage current measurements. Its clamp-based design can make field measurements more convenient while reducing the need for complicated test arrangements in suitable applications.

The combination of auto ranging, auto calibration, data storage, data recall, data hold, backlight, and resistance limit alarm makes the tester easier to use during routine inspection and maintenance tasks.

Its visual and audible alarm functions also provide useful alerts when monitoring resistance limits or other measurement conditions, helping technicians quickly identify readings that require attention.

Who Should Buy the UNI-T UT276A+?

The UT276A+ is suitable for professionals involved in electrical testing, grounding inspection, maintenance, and troubleshooting.

  • Electrical engineers
  • Electrical technicians
  • Electrical contractors
  • Grounding system inspection professionals
  • Industrial maintenance technicians
  • Facility maintenance teams
  • Power system maintenance personnel
  • Electrical safety inspection teams
  • Building maintenance professionals
  • Industrial service technicians
  • Electrical testing professionals

Where Is the UNI-T UT276A+ Used?

The UNI-T UT276A+ Clamp Earth Ground Tester is suitable for professional environments where grounding resistance and leakage current need to be inspected.

  • Electrical installations: Check suitable grounding systems during maintenance and inspection.
  • Industrial facilities: Support routine grounding and electrical maintenance activities.
  • Commercial buildings: Assist with electrical grounding inspections and maintenance.
  • Power distribution systems: Inspect suitable grounding conductors and electrical equipment.
  • Control and distribution cabinets: Assist qualified technicians with grounding and leakage checks.
  • Factories and workshops: Support electrical maintenance and troubleshooting.
  • Facility maintenance: Monitor grounding conditions as part of electrical maintenance programs.
  • Electrical safety inspections: Help technicians investigate grounding resistance and leakage current conditions.

Professional Grounding and Leakage Current Testing

A reliable grounding system is an important part of electrical safety and equipment protection. The UNI-T UT276A+ provides professionals with a dedicated clamp-style instrument for checking grounding resistance and leakage current in suitable electrical systems.

With convenient features such as automatic ranging, automatic calibration, measurement storage, alarms, data recall, and a backlit display, the UT276A+ is designed to support efficient electrical inspection in workshops, commercial facilities, industrial environments, and field service applications.

UNI-T UT276A+ Clamp Earth Ground Tester FAQ

What is the UNI-T UT276A+ used for?

The UNI-T UT276A+ is used to measure earth ground resistance and leakage current in suitable electrical grounding systems. It is designed for electrical inspection, maintenance, troubleshooting, and grounding checks.

What type of tester is the UT276A+?

The UT276A+ is a clamp earth ground tester that combines grounding resistance and leakage current measurement functions in a portable handheld instrument.

Can the UT276A+ measure leakage current?

Yes. The UNI-T UT276A+ supports leakage current measurement and can be used by qualified technicians to investigate leakage current conditions in suitable electrical systems.

Does the UT276A+ have automatic ranging?

Yes. The UT276A+ features auto ranging, helping the instrument select an appropriate measurement range for the measured value.

Does the UNI-T UT276A+ store measurement data?

Yes. The UT276A+ can store up to 300 measurement records, allowing users to recall measurements for later reference.

Does the UT276A+ have a resistance alarm?

Yes. The UT276A+ includes a resistance limit alarm with visual and audible indications to help alert users when configured measurement conditions are exceeded.

Does the UT276A+ have a backlit display?

Yes. The UNI-T UT276A+ features an LCD backlight to improve visibility when working in low-light conditions.

What is the clamp jaw opening of the UT276A+?

The UNI-T UT276A+ has a 32mm clamp jaw opening, providing a practical size for suitable grounding and electrical measurement applications.

Is the UT276A+ suitable for industrial maintenance?

Yes. The UT276A+ is suitable for grounding and leakage current inspection in industrial facilities, workshops, commercial buildings, and other professional electrical maintenance environments.

Who should use the UNI-T UT276A+?

The UT276A+ is intended for appropriately trained electrical engineers, technicians, contractors, maintenance professionals, and other qualified personnel who perform grounding and electrical inspections.

Buy UNI-T UT276A+ Clamp Earth Ground Tester

Choose the UNI-T UT276A+ Clamp Earth Ground Tester for convenient professional inspection of earth ground resistance and leakage current. With automatic measurement functions, data storage and recall, alarms, LCD backlight, and a practical clamp design, it is a versatile tool for electrical maintenance, grounding inspection, and troubleshooting applications.

Reviews (0)

No reviews yet. Be the first to review this product!

Chat With Us